                首頁 > 產(chǎn)品展示 > > 其他檢測儀器 > TC-500 氧氮聯(lián)合測定儀

                TC-500 氧氮聯(lián)合測定儀

                簡要描述:簡單說明:TC500系列儀器質(zhì)量、性能、工藝滿足您對金屬、難熔物、其他無機材料日常生產(chǎn)中氮/氧分析的需要

                • 產(chǎn)品型號:TC-500
                • 廠商性質(zhì):生產(chǎn)廠家
                • 更新時間:2024-10-08
                • 訪  問  量:1917
                詳情介紹

                詳細說明:

                TC500系列儀器質(zhì)量、性能、工藝滿足您對金屬、難熔物、其他無機材料日常生產(chǎn)中氮/氧分析的需要

                Determination of Oxygen and Nitrogen in
                Reactive/Refractory Metals and Their Alloys*
                 
                Approval
                ASTM E-1409 Oxygen Determination in Titanium and Titanium Alloys
                ASTM E-1569 Oxygen Determination in Tantalum
                ASTM E-1937 Nitrogen Determination in Titanium and Titanium Alloys
                 
                Sample Preparation
                A clean representative sample is required in order to obtain optimum results. Solid samples can be leached in suitable acid or abraded with a clean file, rinsed in acetone, and dried with warm air. Refer to ASTM methods above for further details.
                 
                Accessories
                782-720 Crucible; 782-721 Electrode Tip; 502-344 UHP Nickel
                Baskets; 501-073 Graphite; 503-032 Glass Accelerator Scoop;
                501-059 Tin Capsules—for powdered samples. (Additional steps required for powdered samples are noted in parenthesis.)
                 
                Calibration Standard
                LECO 501-320 Titanium Pin, 502-047 Zirconium Pin, NIST, or other suitable reactive/refractory metal standard.
                 
                Method Parameters
                Analysis Parameters
                Outgas Cycles                           2
                Analysis Delay (seconds)             20
                Analysis Comparator                 1
                Analysis Type                              Auto
                 
                Element Parameters                  Oxygen           Nitrogen
                Minimum Time (seconds)
                35
                55
                Integration Delay (seconds)
                5
                15
                Comparator Level (%)
                1
                1
                 
                Furnace Parameters
                Furnace Control Mode             Power
                Purge Time (seconds)                    15
                Outgas Time (seconds)                20
                Cool Time (seconds)                    5
                Outgas Power (Watts)                 6300
                Analyze Power (Watts)                5300
                 
                 
                 
                 
                 


                 

                *This includes Ti, Zr, W, Mo, Ta, Nb, Hf, and their alloys.

                 
                TC500


                 

                 
                Typical Results
                 
                 
                 
                Titanium Pin
                Mass (g)
                Oxygen (%)
                Nitrogen (%)
                 
                0.1135
                0.1808
                0.0189
                 
                0.1133
                0.1843
                0.0194
                 
                0.1134
                0.1831
                0.0184
                 
                0.1138
                0.1819
                0.0188
                 
                0.1133
                0.1821
                0.0195
                 
                0.1131
                0.1829
                0.0185
                 
                0.1134
                0.1833
                0.0191
                 
                0.1143
                0.1849
                0.0194
                 
                0.1125
                0.1837
                0.0189
                 
                0.1072
                0.1830
                0.0191
                 
                Average
                0.1830
                0.0190
                 
                Std. Dev.
                0.0012
                0.0004
                 
                Zirconium Wire
                 
                Mass (g)
                 
                Oxygen (%)
                 
                Nitrogen (%)
                 
                0.1067
                0.1246
                0.0017
                 
                0.0978
                0.1273
                0.0017
                 
                0.1180
                0.1246
                0.0019
                 
                0.1097
                0.1235
                0.0014
                 
                0.1141
                0.1272
                0.0017
                 
                0.1017
                0.1226
                0.0018
                 
                0.1140
                0.1269
                0.0020
                 
                0.0987
                0.1239
                0.0020
                 
                0.1015
                0.1233
                0.0022
                 
                0.1197
                0.1270
                0.0020
                 
                Average
                0.1251
                0.0018
                 
                Std. Dev.
                0.0018
                0.0002
                 
                Procedure
                 
                 
                 
                1.   Determine the blank as follows:
                a.   Enter the "blank" ID code with a 1.0000 g weight in the weight stack.
                b.   Press the loader control switch, the sample loader will open.
                c.   Place one 502-344 UHP Nickel basket into the loading head using clean tweezers.
                (Place a 501-059 Tin capsule into the Nickel basket before placing it in the loading head.)
                d.   Press the loader control switch, the sample loader will close and seal and the furnace electrode will open.
                e.   Remove crucible from electrode tip and discard.  Clean furnace area using the appropriate brushes.  Vacuum away loose dust.
                f.    Place ~0.05 g 501-073 into the bottom of a 782-720 crucible.  ~0.05 g is approximay a ¼ full
                503-032 glass accelerator scoop.
                g.   Place the crucible on the lower electrode.
                h.   Press the loader control switch, the furnace electrode will close and the analysis sequence will start automatically.
                i.    Repeat steps 1a through 1h at least four more times.
                j.    Enter blank following routine outlined in operator's instruction manual.
                2.   Calibrate the instrument as follows:
                a.   Weigh the calibration sample. (Weigh the calibration sample into the tin capsule.)
                b.   Enter the calibration sample ID code and sample weight in the weight stack.
                c.   Place the calibration sample (capsule) into a nickel basket.
                d.   Press the loader control switch, the sample loader will open.
                e.   Carefully place the calibration sample/nickel basket (capsule) into the loading head using clean tweezers.  Make sure that the calibration sample (capsule) stays in the basket and the basket
                stays upright.
                f.    Press the loader control switch, the sample loader will close and seal and the furnace electrode will open.
                continued on page 3


                 

                Procedure (continued from page 2)
                g.   Remove crucible from electrode tip and discard.  Clean furnace area using the appropriate brushes.  Vacuum away loose dust.
                h.   Place ~0.05 g graphite into the bottom of a crucible.
                i.    Place the crucible on the lower electrode.
                j.    Press the loader control switch, the furnace electrode will close and the analysis sequence will start automatically.
                k.   Repeat steps 2a through 2j a minimum of three times.
                l.    Complete a calibration by following the auto calibration procedure as outlined in the operator's instruction manual.
                m.  Verify the calibration by analyzing the calibration sample again.  It should fall within the expected tolerances.  If not, repeat steps 2a through 2l again.
                3.   Analyze the samples as follows:
                a.   Weigh ~0.1 g sample. (Weigh the sample into the tin capsule.)
                b.   Enter the sample ID code and sample weight in the weight stack.
                c.   Place the sample (capsule) into a nickel basket.
                d.   Press the loader control switch, the sample loader will open.
                e.   Carefully place the sample/nickel basket (capsule) into the loading head using clean tweezers.
                Make sure that the sample (capsule) stays in the basket and the basket stays upright.
                f.    Press the loader control switch, the sample loader will close and seal and the furnace electrode will open.
                g.   Remove crucible from electrode tip and discard.  Clean furnace area using the appropriate brushes.  Vacuum away loose dust.
                h.   Place ~0.05 g graphite into the bottom of a crucible.
                i.    Place the crucible on the lower electrode.
                j.    Press the loader control switch, the furnace electrode will close and the analysis sequence will start automatically.
                 
                Theory of Operation
                The TC500 is a microprocessor-based, software-controlled instrument that measures both nitrogen and oxygen in a wide variety of metals, refractories, and inorganic materials. The inert gas fusion principle is employed. A weighed sample, placed in a high-purity graphite crucible, is fused under a flowing helium gas stream at temperatures sufficient to release oxygen, nitrogen, and hydrogen. The oxygen in the
                sample, combines with the carbon from the crucible to form carbon monoxide. The nitrogen present in
                the sample releases as molecular nitrogen, and any hydrogen present is released as hydrogen gas. The helium carries the sample gases through heated rare earth copper oxide which converts carbon
                monoxide to carbon dioxide (CO2) and hydrogen to water (H2O). The nitrogen passes through
                unchanged. The gases are then passed through a CO2  infrared (IR) cell where the oxygen is measured as
                CO2. CO2  and H2O are then removed by a Lecosorb/Anhydrone trap, while the nitrogen passes through
                to a thermal conductivity (TC) cell for determination.


                 

                TC500 Flow Diagram
                 
                 
                 
                 
                 

                留言框

                • 產(chǎn)品:

                • 您的單位:

                • 您的姓名:

                • 聯(lián)系電話:

                • 常用郵箱:

                • 省份:

                • 詳細地址:

                • 補充說明:

                • 驗證碼:

                  請輸入計算結果(填寫阿拉伯數(shù)字),如:三加四=7
                ©2025 版權所有:寧波市鄞州瑾瑞儀器設備有限公司   備案號:浙ICP備14028217號-3

                浙公網(wǎng)安備33020402000311號

                欧美日韩不卡在线_新婚人妻少妇系列28部分_年轻的小婊孑4伦理_亚洲av欧美av色婷婷伊人_来一水AV@lysav
              1. <td id="vzf6p"><tr id="vzf6p"></tr></td>
                  1. 
                    

                            <td id="vzf6p"><tr id="vzf6p"><th id="vzf6p"></th></tr></td>
                            盖州市| 朝阳县| 正宁县| 兰坪| 蓬溪县| 海伦市| 库车县| 兰溪市| 腾冲县| 锦屏县| 体育| 仁寿县| 韶关市| 新民市| 同心县| 汝城县| 南郑县| 晋中市| 万盛区| 屏东县| 祁连县| 万山特区| 阜平县| 中卫市| 鹤庆县| 泸溪县| 遂昌县| 长治市| 蕉岭县| 海兴县| 西充县| 色达县| 阜康市| 永善县| 炉霍县| 沐川县| 襄樊市| 湘潭市| 宁夏| 故城县| 贞丰县|